Z-Test Standard RF Test Cable

Drawing

1. Materials and Plating

Structure

Material

Plating

Body (SMA)

Stainless Steel             

Passivation

Contact PIN

Be-Cu

Gold

Insulator

Teflon

N/A

2. Electrical Characteristics

Impedance

50 ohm

Voltage Rating

335 V(rms)

Frequency Range

DC 0~26.5GHz

Withstanding Voltage

1000 V

Center Contact Resistance

≤3.0 mOhm

Outer Contact Resistance

≤2.0 mOhm

Insulation Resistance

≥1000 Mohm

Shielding Effectiveness

>100 dB

VSWR

≤1.15:1 (DC 0~6GHz)

≤1.20:1 (DC 0~18GHz)

≤1.25:1 (DC 0~26.5GHz)

Cable Insertion Loss

≤1.12dB/M (DC 0~6GHz)

≤2.24dB/M (DC 0~18GHz)

≤2.90dB/M (DC 0~26.5GHz)

3. Mechanical Characteristics

Durability

≥ 500 cycles

Cable Retention Force

≥ 30 LBS

4. Environmental Characteristics

Operation Temperature Range

-40 °C ~ +85 °C

Acculine-01